Home > LYSAGHT® SMARTRUSS™

LYSAGHT® SMARTRUSS™

LYSAGHT® SMARTRUSS™ is a roof truss system that offers durability, affordability, strength and stability. The system is convenient and cost effective, as well as quick and easy to deliver and assemble on
site.

LYSAGHT® SMARTRUSS™ system is manufactured from high tensile strength, long life TRUECORE® steel that is backed by a material warranty* of up to 50 years. It provides a lightweight alternative to timber roof framing and
is competitively priced as the system’s structural integrity leads to lower lifetime costs.

Engineered for strength, LYSAGHT® SMARTRUSS™ roof truss system does not compromise on safety and quality. It is subjected to comprehensive and rigorous testing processes conducted in Lysaght Technology’s world-class
National Association of Testing Authorities (NATA )-accredited structural testing laboratory. Full truss test rig and web compression, torsion bearing, and bottom chord tension tests are conducted to guarantee the system’s structural integrity.

APPLICATIONS
LYSAGHT® SMARTRUSS™ is a Fast, Efficient and Well-Engineered solution for general building applications in residential, commercial and institutional projects
• Fully designed and tested to Australian standards.
• Supported by LYSAGHT® SUPRACADD® detailing software which models the geometry, designs the roof trusses and facilitates fabrication by approved licensed fabricators.
*Warranty terms and conditions apply
• Will not warp, twist, shrink or rot, and no inherent weaknesses such as knots or cracks.
• Reduced builder call backs, no shrinkage, popping nails or rippled walls, ceiling or roofs.
• Termite and insect resistant.
• Fire resistant, non combustible.
• No roof sag, engineered pre-cambering ensures no wavy roof lines.
• Easy frame erection, lightweight and accurate frames are safe and easy to handle and fabricate on-site.
• Design flexibility as high strength to weight provides larger spans, fewer supports for traditional building methods.
• Additions for renovation purposes can be made after construction. Original steel structure will be straight and true regardless of age, and the job of lining up the extension

METAL ROOFING  
Web Chords

C-Channel Sections

Height : 100mm and 75mm

Design Standard Australian Standard AS4600 and prevailing wind loads of the region
 
Load Design (CP3)
 

- Live load on roof

- Metal Roof (inclusive truss self-wt)

- Ceiling Board + Timber Joist/Batten

- General Wind Speed

0.25KN/ m2

0.22KN/ m2

0.13KN/ m2

33m/sec

 
Structure Design (AS4600)
 

- Truss deflection (permanent loads only)

- Batten deflection

Span/250

Span/150

Roof Battens LYSAGHT®TOPSPAN® Manufactured from same material as web and chord
Base Steel Standard Australian Standard AS 1397 - 1993

Min 550MPa for steel < 1mm

Min 450MPa for steel > 1mm

Sections < 1mm thick Protective metallic alloy coating Zinc (43.5%), aluminium (55%) and silicon (1.5%) applied by hot dip process. Coating thickness on both sides 0.05mm (total) as in AS 1397 - 1993 for coating class Z275
Sections < 1mm thick Protective metallic alloy coating applied by hot dip process Coating thickness on both sides 0.05mm (total) as in AS 1397 - 1993 for coating class AZ150.
Fasteners Comply with AS 3566 Class 2 All anchor bolts and connecting plates shall be either galvanized or manufactured from the same material as the trusses.
Batten Spacing Metal roof, batten spacing of 1200mm shall be assumed.

 

CONCRETE ROOF TILES  
Webs & Chords

C-Channel Sections

Height : 75mm and 100mm

Design Standard Australian Standard AS4600and prevailing wind loads of the region
 
Load Design (CP3)
 

- Live load on roof

- Roof Tile load (inclusive truss self-wt)

- Ceiling Board + Timber Joist/Batten

- General Wind Speed

0.25KN/m2

0.70KN/m2

0.13KN/m2

33m/sec

 
Structure Design (AS4600)
 

- Truss deflection (permanent loads only)

- Batten deflection

Span/250

Span/150

Roof Battens LYSAGHT®TOPSPAN® Manufactured from same material as web and chord.
Base Steel Standard Australian Standard AS 1397 - 1993

Min 550MPa for steel <1mm

Min 450MPa for steel >1mm

Sections < 1mm thick Protective metallic alloy coating Zinc (43.5%), aluminium (55%) and silicon (1.5%) applied by hot dip process. Coating thickness on both sides 0.05mm (total) as in AS 1397 - 1993 for coating class Z275
Sections > 1mm thick Protective metallic alloy coating applied by hot dip process Coating thickness on both sides 0.05mm (total) as in AS 1397 - 1993 for coating class Z275
Fasteners Comply with AS 3566 Class 2 All anchor bolts and connecting plates shall be either galvanized or manufactured from the same material as the trusses.
Batten Spacing Concrete tiles, batten spacing of 330mm shall be assumed.

*This is a general technical specification and may vary in accordance to roof design, and design requirements and variations. Please contact BlueScope Lysaght for reference

 